| CENTRALLY
AIRCONDITIONED APARTMENTS |
Airconditioning
distribution shall be provided as per the standard layout of the
apartment. Any changs in the same shall be to the allottees account |
| STRUCTURE |
|
| RCC-Framed
Structure |
Designed
for Zone-5 as per IS Code No. IS-1893 (PART-I:2002) for earthquake
resistance in structures |
| COMMON
AREAS |
|
| FLOORS |
|
| Building
entrance hall & main lift lobbies Staircases / service lift
lobby |
Combination
of marble & granite Terrazo / Stone |
| WALLS |
|
Building
facade:
Building entrance hall & main lift lobbies |
Exterior
paint
Combination of marble / granite / ceramic cladding, plaster with
acrylic emulsion paint/ wall covering. |
| staircases/service
lifts |
Plaster
with paint |
| APARTMENT
AREAS: |
|
| FLOORS |
|
| All
internal spaces in the Apartment, decks, balconies |
Bare
concrete / IPS |
| WALLS |
|
| All
internal walls within the Apartment |
Bare
concrete / IPS |
| DOORS
& WINDOWS |
|
| Door
frames & internal door shutters |
No
internal doors frames and door shutters will be provided. |
| Entrance
doors (main entrance & service entrance doors) |
Commercial
flush shutter / moulded skin doors with padlock |
| External
doors & Windows |
Aluminium
frames and shutters. |
| Hardware |
Brass/steel/powder
coated aluminium / anodised aluminium |
| Bathrooms
/ Kitchen |
Similar
to other rooms. Will not be finished any further. |
| SERVICES |
|
| ELECTRICAL |
Only
PVC conduits will be provided in the ceiling slabs up to drop points.
Back-up power equivalent to about 20 KVA for typical Apartments,
30KVA for Pent houses & Duplex (s) per apartment considering
70% load factor, however, DG set capacity calculation shall take
into account suitable overall diversity of 60%
No light points, fixtures/switches will be provided. |
| PLUMBING
/ SANITATION |
Vertical
stacks for water supply and drainage will be provided in the shafts
with connecting points provided in the toilets / kitchen.
Limited copper piping for the connection points only.
Internal distribution of water supply & drainage will be done
by the customer according to the internal layouts at his own cost.
Water softening plant for the complex. |
| FIRE
FIGHTING / DETECTION SYSTEM |
Fire
fighting including sprinklers, and detection system shall be provided
as per NBC norms Part IV SP - 7 amendment No. 3, January 1997 |
| LIFTS |
Two
numbers of passenger lifts and one service lift will be provided
pet tower, serving the basements as well. |
| CLUB
FACILITY |
Multipurpose
room, swimming pool and change rooms, one squash court, two tennis
court, gymnasium, steam & sauna, pantry, pool table, Laundromat,
security control room, convenience shop & centralised services.
(Facilities are indicative only, subject to change). |
| GENERAL |
Car
calling system or equivalent system.
Water outlets and drainage for car washing facility within the complex.
Facility for creche / play school with playground. |
| |
Security
system CCTV's / monitoring of limited portion of exteriors periphery,
entrance lobbies & the basement. |
| It
is clarified that this being a semi-finished apartment, following
finishing items will NOT be provided inside the Apartment: |
| 1. |
Flooring
in all the areas. |
| 2. |
Final
plastering/ punning / paint / tiling / cladding on all the walls
in all the rooms. |
| 3. |
Internal
door frames and shutters. |
| 4. |
All
the counters, sanitary fixtures, fittings and accessories in the
toilets & kitchen. |
| 5. |
Conduiting
in the walls for electrical writing, internal wiring, switches and
sockets, light fittings, fans, electrical equipments like geysers
etc. Individual security system. |
| 6. |
CI/PVC
pipes for drainage inside the toilet floors to the connecting point
in the vertical stacks; copper pipes in the walls for water supply
from the water supply risers. |
| 7. |
Any
false ceiling withing the Apartment. |
| 8. |
Any
other finishing items. |
| Thus
substantial additional work is required to be done by the customer
at his own cost and discretion in order to make the Apartment livable.
The customer will have to submit proposed details of interior works
and obtain prior approval of DLF before starting the work within
the Apartment. |